Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 764
Filtrar
1.
Respir Res ; 25(1): 155, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38570835

RESUMO

BACKGROUND: Reference values for lung volumes are necessary to identify and diagnose restrictive lung diseases and hyperinflation, but the values have to be validated in the relevant population. Our aim was to investigate the Global Lung Function Initiative (GLI) reference equations in a representative healthy Austrian population and create population-derived reference equations if poor fit was observed. METHODS: We analysed spirometry and body plethysmography data from 5371 respiratory healthy subjects (6-80 years) from the Austrian LEAD Study. Fit with the GLI equations was examined using z-scores and distributions within the limits of normality. LEAD reference equations were then created using the LMS method and the generalized additive model of location shape and scale package according to GLI models. RESULTS: Good fit, defined as mean z-scores between + 0.5 and -0.5,was not observed for the GLI static lung volume equations, with mean z-scores > 0.5 for residual volume (RV), RV/TLC (total lung capacity) and TLC in both sexes, and for expiratory reserve volume (ERV) and inspiratory capacity in females. Distribution within the limits of normality were shifted to the upper limit except for ERV. Population-derived reference equations from the LEAD cohort showed superior fit for lung volumes and provided reproducible results. CONCLUSION: GLI lung volume reference equations demonstrated a poor fit for our cohort, especially in females. Therefore a new set of Austrian reference equations for static lung volumes was developed, that can be applied to both children and adults (6-80 years of age).


Assuntos
Pulmão , Masculino , Adulto , Criança , Feminino , Humanos , Áustria/epidemiologia , Valores de Referência , Medidas de Volume Pulmonar/métodos , Capacidade Pulmonar Total , Espirometria/métodos , Volume Expiratório Forçado , Capacidade Vital
2.
J Vet Intern Med ; 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38666546

RESUMO

BACKGROUND: Cats in respiratory distress have limited tolerance for manipulation, hindering clinical monitoring. Minute volume (MV) can be utilized to rate dyspnea in humans, but its relationship with respiratory distress in cats remains poorly investigated. HYPOTHESIS: Cats with respiratory distress will show higher MV per kg body weight (MV/BW) than normal cats, and the MV/BW increase will correlate with survival. ANIMALS: Fifty-two cats with respiratory distress from lung parenchymal disease, pleural space disease, lower airway obstruction (LAO), or upper airway obstruction were recruited since 2014. METHODS: This is a prospective observational study. Study cats were placed in a transparent chamber, allowing clinicians to easily observe their breathing status and record ventilation using barometric whole-body plethysmography (BWBP). Ventilatory variables of the 52 cats were compared with those of 14 historic control cats. Follow-up data, including disease category, clinical outcomes, and survival, were prospectively collected. RESULTS: Cats in respiratory distress demonstrated significantly higher MV/BW (397 mL/kg; range, 158-1240) than normal cats (269 mL/kg; range, 168-389; P < .001). Among the etiologies, cats with LAO, parenchymal, and pleural space disease exhibited higher-than-normal MV/BW trends. A cutoff value of 373 mL/kg (1.4-fold increase) indicated abnormally increased breathing efforts (sensitivity, 67%; specificity, 93%). MV/BW was independently associated with increased cardiorespiratory mortality in cats with respiratory distress (adjusted hazard ratio 1.17, 95% confidence interval [CI] 1.02-1.35; P = .03). CONCLUSIONS AND CLINICAL IMPORTANCE: Breathing efforts in cats can be noninvasively quantified using BWBP. Measurement of MV/BW could serve as a prognostic index for monitoring cats experiencing respiratory distress.

3.
Chest ; 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38521181

RESUMO

BACKGROUND: The effects of elexacaftor/tezacaftor/ivacaftor (ETI) on respiratory outcomes for people with cystic fibrosis (CF) were demonstrated by several clinical trials, mainly based on simple spirometry. However, gains in lung function may vary greatly between patients, and predictors of FEV1 change after treatment are still missing. RESEARCH QUESTION: Which ventilatory parameters are involved in the heterogeneity of FEV1 change after 12-month ETI treatment in people with CF with advanced lung disease? STUDY DESIGN AND METHODS: This was a multicenter, observational, prospective cohort study at two major CF centers in Italy. We enrolled 47 adults with CF and advanced lung disease (FEV1 < 40% or actively listed for lung transplant) who started ETI treatment between December 2019 and December 2021. At treatment initiation and after 12 months, patients underwent body plethysmography. Values were compared at the two time points. To assess the relationship between baseline plethysmography measurements and treatment-induced changes in FEV1, we used the Spearman rank correlation coefficient (r) and median quantile regressions. RESULTS: After 12 months of ETI treatment, there was a significant increase in FEV1 % predicted from a median value of 36.0 (25th-75th percentile, 33-39) to 52 (25th-75th percentile, 43-61) (P < .001). Inspiratory capacity/total lung capacity (TLC) ratio also increased from 32.0 (25th-75th percentile, 28.6-36.9) to 36.3 (25th-75th percentile, 33.4-41.3) (P < .001). Specific airway resistance decreased from 263 (25th-75th percentile, 182-405) to 207 (25th-75th percentile, 120-258) (P < .001). Functional residual capacity/TLC ratio decreased from 68.2 (25th-75th percentile, 63.3-71.9) to 63.9 (25th-75th percentile, 58.8-67.1) (P < .001), and residual volume (RV)/TLC ratio decreased from 53.1 (25th-75th percentile, 48.3-59.4) to 45.6 (25th-75th percentile, 39.4-49.8) (P < .001). Changes in FEV1 % predicted negatively correlated with baseline functional residual capacity/TLC ratio (r = -0.38, P = .009) and RV/TLC ratio (r= -0.42, P = .004). After adjustment for age at treatment initiation and cystic fibrosis transmembrane conductance regulator genotype, we estimated that for each 10-unit increase in baseline RV/TLC ratio, the expected median change in FEV1 decreased by 2.3 (95% CI, -5.8 to -0.8). INTERPRETATION: ETI was associated with improvements in both static and dynamic volumes in people with CF and advanced lung disease. Heterogeneity in FEV1 % predicted change after 12 months of treatment may be predicted by the severity of hyperinflation at baseline.

4.
Am J Vet Res ; : 1-7, 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38503051

RESUMO

OBJECTIVE: To compare the accuracy of doppler ultrasound (DOP) and pulse oximeter plethysmography (POP) in the measurement of systolic arterial pressure (SAP) to invasive blood pressure (IBP) in anesthetized dogs. ANIMALS: 40 client-owned healthy dogs > 10 kg. METHODS: Dogs were anesthetized for surgical procedures in dorsal recumbency. Invasive blood pressure was measured from a dorsal pedal artery. DOP and POP device probes were placed over the median caudal artery with a flow-occluding cuff for noninvasive blood pressure measurement. Systolic arterial pressure measured by DOP, loss of pulse oximeter plethysmograph (POPL), and return of pulse oximeter plethysmograph (POPR) were compared to SAP measured by IBP. A linear mixed model was used to determine correlation. Bland-Altman analyses were performed to determine bias, SD, and limits of agreement. The accuracy of DOP and POP was compared to IBP across different tensive states. RESULTS: Conditional R2 values for DOP, POPL, and POPR versus IBP were 0.92, 0.85, and 0.87, respectively (all P < .001). The biases for DOP, POPL, and POPR compared to IBP were +7.6 ± 13.1, +3.9 ± 14.4, and +8.6 ± 15.2 mm Hg (bias ± SD), respectively. Limits of agreement (lower, upper) were (-18.1, +33.3), (-24.3, +32.1), and (-21.2, +38.4) mm Hg for DOP, POPL, and POPR, respectively. DOP and POP overestimated SAP during hypotension (SAP < 90 mm Hg), DOP to a lesser magnitude. CLINICAL RELEVANCE: DOP measured from the median caudal artery may be acceptable for SAP measurement in dorsally recumbent, healthy anesthetized dogs > 10 kg. POP was determined an unacceptable method.

5.
J Vasc Surg Venous Lymphat Disord ; : 101869, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38460817

RESUMO

OBJECTIVE: Reduced calf muscle pump function (CPF) is an independent risk factor for venous thromboembolism and mortality. We aimed to evaluate the relationship between handgrip strength (HGS) and CPF. METHODS: Patients referred to the Gonda Vascular Laboratory for noninvasive venous studies were identified and consented. Patients underwent standard venous air plethysmography protocol. CPF (ejection fraction) was measured in each lower extremity of ambulatory patients by comparing refill volume after ankle flexes and passive refill volumes. The cutoff for reduced CPF (rCPF) was defined as an ejection fraction of <45%. Maximum HGS bilaterally was obtained (three trials per hand) using a dynamometer. HGS and CPF were compared (right hand to calf, left hand to calf) and the correlation between the measures was evaluated. RESULTS: 115 patients (mean age, 59.2 ± 17.4 years; 67 females, mean body mass index, 30.83 ± 6.46) were consented and assessed for HGS and CPF. rCPF was observed in 53 right legs (46%) and 67 left legs (58%). CPF was reduced bilaterally in 45 (39%) and unilaterally in 30 (26%) patients. HGS was reduced bilaterally in 74 (64.3%), unilaterally in 23 (20%), and normal in 18 (15.7%) patients. Comparing each hand/calf pair, no significant correlations were seen between HGS and CPF. The Spearman's rank correlation coefficients test yielded values of 0.16 for the right side and 0.10 for the left side. CONCLUSIONS: There is no significant correlation between HGS and CPF, demonstrating that HGS measurements are not an acceptable surrogate for rCPF, indicating different pathophysiological mechanisms for each process.

6.
Pediatr Allergy Immunol Pulmonol ; 37(1): 7-12, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38484265

RESUMO

Background: Structured light plethysmography (SLP) is a novel light-based method that captures chest wall movements to evaluate tidal breathing. Methods: Thirty-two children who underwent lung surgery were enrolled. Their clinical history was collected along with spirometry and SLP. Results: Median age of surgery was 9 months (interquartile range 4-30). Most frequent diagnosis was congenital pulmonary airway malformation (14/32), then pulmonary sequestration (9/32), tumor (5/32), and bronchogenic cyst (4/32). The most frequent surgical approach was lobectomy (59%), segmentectomy (38%), and complete resection (3%). More than 80% had surgery when younger than 3 years of age. Eight patients had short-term complications (pleural effusion was the most frequent), while long-term effects were reported in 15 patients (19% recurrent cough, 13% thoracic deformities, 13% airway infections, 9% wheezing, 6% reduced exercise tolerance, and 3% columnar deformities). Spirometry was normal in 9/22 patients. Nine patients had a restrictive pattern, while 4 showed a mild bronco-reactivity. Ten patients did not perform spirometry because of young age. SLP revealed the presence of obstructive pattern in 10% of patients (IE50 > 1.88) and showed a significant difference between the two hemithorax in 29% of patients. Discussion: SLP may be a new method to evaluate lung function, without collaboration and radiation exposure, in children who underwent lung resection, also in preschool age.


Assuntos
Pletismografia , Procedimentos Cirúrgicos Pulmonares , Criança , Pré-Escolar , Humanos , Lactente , Pletismografia/métodos , Respiração , Espirometria/métodos , Pulmão/cirurgia
7.
Int. j. clin. health psychol. (Internet) ; 24(1): [100442], Ene-Mar, 2024. ilus, tab
Artigo em Inglês | IBECS | ID: ibc-230383

RESUMO

Background/Objective: Men do not use external condoms for several reasons, which can result in public health problems. One of these is related to Condom-Associated Erectile Problems. This study aimed to examine the sexual arousal response of heterosexual men when using an external condom made of synthetic resin type AT-10. Method: A total of 82 Colombian young men (Mage = 23.17 years, SD = 3.04, age range = 18–30) participated in this experimental study. Two random groups (experimental and control; n = 41 each) were compared. The experimental group used condoms, whereas the control group did not. Fit and feel condom perceptions, initial erectile scores, age, and substance use were controlled for. Erection was measured while viewing a sexual video by using penile plethysmography and subjective arousal. Results: The results, obtained from comparing the experimental group (using pre-erection condoms) with the control group (not using condoms), revealed no significant difference in both subjective and physiological sexual arousal. This suggests that pre-erection condoms do not have an effect on the erectile response. Discussion: More research is needed in this area to provide treatment and clinical interventions or sexual and reproductive education to mitigate the occurrence of sexual dysfunction, unplanned pregnancies, or sexually transmitted infections. Also, research addresses public health issues related to the prevention and/or intervention of sexual risk behaviors and sexual dysfunctions, highlighting their significance in sexual education and clinical practice.(AU)


Assuntos
Humanos , Masculino , Preservativos , Pletismografia , Ereção Peniana , Disfunção Erétil , Colômbia , Psicologia Clínica , Psicologia
8.
Clin Res Cardiol ; 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38315211

RESUMO

AIMS: In each cardiopulmonary exercise test (CPET), resting spirometry is performed in advance. In patients with a congenital heart defect (CHD), lung volumes are often impaired. This study investigates correlations between lung volumes and CPET parameters and determines, whether body plethysmography provides substantial additional information for these patients. METHODS: Data from 102 patients (23.8 ± 10.4 years of age, 39 female) with various forms of CHD were examined from April 2018 to October 2022. All patients underwent spirometry (measuring forced vital capacity, FVC and forced expiratory volume in 1 s, FEV1), body plethysmography (measuring total lung capacity, TLC) and an exhausting CPET. Data is presented as the median and interquartile range (z-scores) and correlated with Spearman's rho. RESULTS: Fifty-five% of all patients had normal results in lung function and 45% had normal peak oxygen uptake (≥ 80% predicted in peak VO2). Patients with impaired lung function were significantly more likely to have low exercise capacity (Fisher's exact test: p = 0.028). FVC z-values and %predicted peak VO2 (r = 0.365, p < 0.001) correlated significantly as well as FEV1_z and %predicted peak VO2 (r = 0.320, p = 0.001), and TLC z-values and %predicted peak VO2 (r = 0.249, p = 0.012). No correlation was found between FEV1/FVC z-values and %predicted peak VO2 (r = -0.043, p = 0.670). CONCLUSION: Spirometry and exercise capacity positively correlate, also in CHD patients. However, body plethysmography does not provide additional or improved prediction and is therefore only recommended in noteworthy results in spirometry to exclude further lung co-morbidities.

9.
J Biomed Phys Eng ; 14(1): 67-78, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38357601

RESUMO

Background: The effect of position and gender on chest movements and respiratory volumes is controversial and investigated in only a few studies. Objective: This study aimed to investigate the effects of position and gender on the breathing pattern during four different positions in healthy individuals. Material and Methods: In this cross-sectional study, twenty-eight (14 males, 14 females) healthy individuals participated aged 20-45 years. The optoelectronic plethysmography (OEP) method was used for the three-dimensional evaluation of chest wall motions and the compartmental analysis of the breathing pattern in supine, sitting, standing, and active straight leg raised (ASLR) positions. Volume changes in different parts of the chest wall were also measured. Results: Position affected total and compartmental respiratory volumes in both genders. Respiratory volumes decreased in the supine position compared to sitting and standing. Total and abdominal respiratory volumes also decreased in females when comparing supine positions with the ASLR. A higher pulmonary rib cage contribution was identified in females, and males exhibited higher abdominal rib cage volume compared with females. Conclusion: The breathing pattern was affected by position and gender, and the respiratory volumes increased in more upright positions, perhaps due to a greater gravitational load. The ASLR decreases the respiratory volume, which is probably due to increased postural demand.

10.
Int J Clin Health Psychol ; 24(1): 100442, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38348144

RESUMO

Background/Objective: Men do not use external condoms for several reasons, which can result in public health problems. One of these is related to Condom-Associated Erectile Problems. This study aimed to examine the sexual arousal response of heterosexual men when using an external condom made of synthetic resin type AT-10. Method: A total of 82 Colombian young men (Mage = 23.17 years, SD = 3.04, age range = 18-30) participated in this experimental study. Two random groups (experimental and control; n = 41 each) were compared. The experimental group used condoms, whereas the control group did not. Fit and feel condom perceptions, initial erectile scores, age, and substance use were controlled for. Erection was measured while viewing a sexual video by using penile plethysmography and subjective arousal. Results: The results, obtained from comparing the experimental group (using pre-erection condoms) with the control group (not using condoms), revealed no significant difference in both subjective and physiological sexual arousal. This suggests that pre-erection condoms do not have an effect on the erectile response. Discussion: More research is needed in this area to provide treatment and clinical interventions or sexual and reproductive education to mitigate the occurrence of sexual dysfunction, unplanned pregnancies, or sexually transmitted infections. Also, research addresses public health issues related to the prevention and/or intervention of sexual risk behaviors and sexual dysfunctions, highlighting their significance in sexual education and clinical practice.

11.
Chem Biol Interact ; 392: 110929, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38417730

RESUMO

Despite the international convention on the prohibition of chemical weapons ratified in 1997, the threat of conflicts and terrorist attacks involving such weapons still exists. Among these, organophosphorus-nerve agents (OPs) inhibit cholinesterases (ChE) causing cholinergic syndrome. The reactivation of these enzymes is therefore essential to protect the poisoned people. However, these reactivating molecules, mainly named oximes, have major drawbacks with limited efficacy against some OPs and a non-negligible ChE inhibitor potential if administered at an inadequate dose, an effect that they are precisely supposed to mitigate. As a result, this project focused on assessing therapeutic efficacy, in mice, up to the NOAEL dose, the maximum dose of oxime that does not induce any observable toxic effect. NOAEL doses of HI-6 DMS, a reference oxime, and JDS364. HCl, a candidate reactivator, were assessed using dual-chamber plethysmography, with respiratory ventilation impairment as a toxicity criterion. Time-course modeling parameters and pharmacodynamic profiles, reflecting the interaction between the oxime and circulating ChE, were evaluated for treatments at their NOAEL and higher doses. Finally, the therapeutic potential against OPs poisoning was determined through the assessment of protective indices. For JDS364. HCl, the NOAEL dose corresponds to the smallest dose inducing the most significant therapeutic effect without causing any abnormality in ChE activity. In contrast, for HI-6 DMS, its therapeutic benefit was observed at doses higher than its NOAEL, leading to alterations in respiratory function. These alterations could not be directly correlated with ChE inhibition and had no adverse effects on survival. They are potentially attributed to the stimulation of non-enzymatic cholinergic targets by HI-6 DMS. Thus, the NOAEL appears to be an optimal dose for evaluating the efficacy of oximes, particularly when it can be linked to respiratory alterations effectively resulting from ChE inhibition.


Assuntos
Substâncias para a Guerra Química , Reativadores da Colinesterase , Agentes Neurotóxicos , Humanos , Camundongos , Animais , Reativadores da Colinesterase/farmacologia , Reativadores da Colinesterase/uso terapêutico , Reativadores da Colinesterase/química , Agentes Neurotóxicos/toxicidade , Nível de Efeito Adverso não Observado , Substâncias para a Guerra Química/toxicidade , Oximas/farmacologia , Oximas/uso terapêutico , Oximas/química , Compostos de Piridínio/farmacologia , Inibidores da Colinesterase/toxicidade , Inibidores da Colinesterase/química , Colinesterases , Acetilcolinesterase , Antídotos/farmacologia , Antídotos/uso terapêutico
12.
Vascular ; : 17085381241236927, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38414094

RESUMO

OBJECTIVES: Chronic venous insufficiency is mainly caused by reflux, obstruction, or both. Endovenous glue ablation has become one of the widely used methods for treating reflux in recent years. Duplex ultrasonography is the most commonly used method for diagnosing and evaluating treatment. However, there is important information that plethysmographic venous hemodynamics provides, which Duplex USG cannot provide. This retrospective study aimed to evaluate the 5-year clinical, anatomical, and hemodynamic results of endovenous glue ablation in the treatment of chronic venous insufficience, accompanied by the data from the plethysmographic study. PATIENTS AND METHOD: Between January 2018 and August 2018, 133 patients with symptomatic CEAP 2-6 varicose veins with reflux of the great saphenous vein lasting longer than 0.5 seconds and a diameter of 5.5 mm in the standing great saphenous vein underwent EVGA. CEAP, VCSS, CIVIQ 20, Doppler USG, GSV diameters and insufficiency times, and hemodynamically Venous Refilling Time and Venous Half-Value Time measurements were performed before the procedure. In the same way, measurements were made at the 1st, 3rd, 6th, 12th, 24th, and 60th months of the patients who were called and came to the postoperative follow-up. RESULTS: Procedural success was 100%, and complete occlusion was observed %93 after treatment, at the 60 month. The improvement in VCSS (from 4.4 ± 1.3 to 1.7 ± 0.9), CIVIQ20 (from 8.5 ± 3.1 to 4.7 ± 2.0), VRT (from 20.3 ± 5.0 to 131.1 ± 4.0), and TH (from 2.8 ± 0.3 to 2.4 ± 0.2) was significant (p < .001 was for all). CONCLUSION: Endovenous glue ablation is a preferred method for the treatment of great saphenous vein insufficiency due to its ease of use and the comfort it provides to patients, as well as its effectiveness and safety. In particular, it can be considered an effective method for improving venous hemodynamics and relieving associated symptoms.

13.
Bioengineering (Basel) ; 11(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38391633

RESUMO

Cardiovascular diseases are a leading global cause of mortality. The current standard diagnostic methods, such as imaging and invasive procedures, are relatively expensive and partly connected with risks to the patient. Bioimpedance measurements hold the promise to offer rapid, safe, and low-cost alternative diagnostic methods. In the realm of cardiovascular diseases, bioimpedance methods rely on the changing electrical conductivity of blood, which depends on the local hemodynamics. However, the exact dependence of blood conductivity on the hemodynamic parameters is not yet fully understood, and the existing models for this dependence are limited to rather academic flow fields in straight pipes or channels. In this work, we suggest two closely connected anisotropic electrical conductivity models for blood in general three-dimensional flows, which consider the orientation and alignment of red blood cells (RBCs) in shear flows. In shear flows, RBCs adopt preferred orientations through a rotation of their membrane known as tank-treading motion. The two models are built on two different assumptions as to which hemodynamic characteristic determines the preferred orientation. The models are evaluated in two example simulations of blood flow. In a straight rigid vessel, the models coincide and are in accordance with experimental observations. In a simplified aorta geometry, the models yield different results. These differences are analyzed quantitatively, but a validation of the models with experiments is yet outstanding.

14.
Front Nutr ; 11: 1280425, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38385007

RESUMO

Background: While several methodologies are available to measure adiposity, few have been validated in sub-Saharan African (SSA) and none in postpartum African women living with HIV (WLHIV). We compared bioelectrical impendence analysis (BIA) and air displacement plethysmography (ADP) against dual x-ray absorptiometry (DXA) in South African women and examined differences by HIV and body mass index (BMI) status. Methods: Lin's concordance correlation coefficient (CCC) test was used to examine fat mass (FM), fat free mass (FFM), and total body fat percent (%BF) difference between BIA vs. DXA, and ADP vs. DXA in women living with HIV (n = 57) and without HIV (n = 25). The Bland Altman test was used to assess mean differences and the direction of bias. Results: The median age was 31 years (IQR, 26-35) and months postpartum were 11 (IQR, 7-16), 44% of the women had obesity. Lin's CCC for BIA and ADP vs. DXA were both 0.80 for %BF and 0.97 for FM, and 0.86 and 0.80 for FFM, respectively. Mean differences (DXA-BIA and ADP estimates) were 0.22 ± 4.54% (p = 0.54) and 3.35 ± 3.27% (p < 0.01) for %BF, -0.82 ± 3.56 kg (p = 0.06) and 1.43 ± 2.68 kg (p = 0.01) for FM, -1.38 ± 3.61 kg (p = 0.01) and - 3.34 ± 2.37 kg (p < 0.01) for FFM, respectively. BIA overestimated %BF in WLHIV and underestimated it in women with obesity. Conclusion: Body composition measurements using BIA and ADP correlated well with DXA, thereby providing alternative, safe tools for measuring postpartum FM and FFM in SSA women, including WLHIV.

15.
Respir Care ; 69(4): 415-421, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38167212

RESUMO

BACKGROUND: Impulse oscillometry (IOS) is a noninvasive technique that measures lung physiology independently of patient effort. In the present study, we aimed to investigate the utility of IOS parameters in comparison with pulmonary function testing (PFT) among hospitalized subjects, with emphasis on obstructive and small airway diseases. METHODS: Sixty-one subjects hospitalized either with unexplained dyspnea or for pre-surgery evaluation were included in the study. All subjects underwent PFTs and IOS test. The correlation between IOS results and PFTs was examined in different subgroups. The ability of IOS parameters to predict abnormal PFTs was evaluated using the area under the receiver operating characteristic (ROC) curve, and optimal cutoff values were calculated. RESULTS: IOS results were found to correlate with PFT values. Subgroup analysis revealed that these correlations were higher in younger (age < 70) and non-obese (body mass index < 25kg/m2) subjects. The resonant frequency was an independent predictor and had the best predictive ability for abnormal FEV1/FVC (area under the ROC curve 0.732 [95% CI 0.57-0.90], optimal cutoff 17 Hz, 87% sensitivity, 62% specificity) and abnormal forced expiratory flow during the middle half of the FVC maneuver (area under the ROC curve 0.667 [95% CI 0.53-0.81], optimal cutoff 15 Hz, 77% sensitivity, 54% specificity). Area of reactance and the difference in respiratory resistance at 5 Hz and 20 Hz also showed a good predictive ability for abnormal FEV1/FVC (area under the ROC curve 0.716 and 0.730, respectively). CONCLUSIONS: We found that the IOS performed well in diagnosing small airway and obstructive diseases among hospitalized subjects. IOS might serve as an alternative to standard PFTs in non-cooperative or dyspneic hospitalized patients.


Assuntos
Asma , Doença Pulmonar Obstrutiva Crônica , Adulto , Humanos , Oscilometria/métodos , Espirometria , Testes de Função Respiratória/métodos , Dispneia , Volume Expiratório Forçado
16.
Artigo em Inglês | MEDLINE | ID: mdl-38265049

RESUMO

AIM: To determine the validity of bioelectrical impedance analysis (BIA) in quantifying fat-free mass (FFM) compared to air-displacement plethysmography (ADP) in patients with a motor neurone disease (MND). METHODS: FFM of 140 patients diagnosed with MND was determined by ADP using the BodPod (i.e. the gold standard), and by BIA using the whole-body Bodystat. FFM values were translated to predicted resting energy expenditure (REE); the actual REE was measured using indirect calorimetry, resulting in a metabolic index. Validity of the BIA compared to the ADP was assessed using Bland-Altman analysis and Pearson's r. To assess the clinical relevance of differences, we evaluated changes in metabolic index and in individualized protein demand. RESULTS: Despite the high correlation between ADP and BIA (r = 0.93), averaged across patients, the assessed mean fat-free mass was 51.7 kg (± 0.9) using ADP and 54.2 kg (± 1.0) using BIA. Hence, BIA overestimated fat-free mass by 2.5 kg (95% CI 1.8-3.2, p < 0.001). Clinically, an increased metabolic index would be more often underdiagnosed in patients with MND using BIA (31.4% according to BIA versus 44.2% according to ADP, p = 0.048). A clinically relevant overestimation of ≥ 15 g in protein demand was observed for 4 (2.9%) patients using BIA. CONCLUSIONS: BIA systematically overestimates FFM in patients with MND. Although the differences are limited with ADP, underscoring the utility of BIA for research, overestimation of fat-free mass may have consequences for clinical decision-making, especially when interest lies in determining the metabolic index.


Assuntos
Esclerose Amiotrófica Lateral , Doença dos Neurônios Motores , Humanos , Composição Corporal , Estudos Transversais , Pletismografia/métodos , Impedância Elétrica , Reprodutibilidade dos Testes , Doença dos Neurônios Motores/diagnóstico
17.
Sensors (Basel) ; 24(2)2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38257664

RESUMO

In overcoming the worldwide problem of overweight and obesity, automatic dietary monitoring (ADM) is introduced as support in dieting practises. ADM aims to automatically, continuously, and objectively measure dimensions of food intake in a free-living environment. This could simplify the food registration process, thereby overcoming frequent memory, underestimation, and overestimation problems. In this study, an eating event detection sensor system was developed comprising a smartwatch worn on the wrist containing an accelerometer and gyroscope for eating gesture detection, a piezoelectric sensor worn on the jaw for chewing detection, and a respiratory inductance plethysmographic sensor consisting of two belts worn around the chest and abdomen for food swallowing detection. These sensors were combined to determine to what extent a combination of sensors focusing on different steps of the dietary cycle can improve eating event classification results. Six subjects participated in an experiment in a controlled setting consisting of both eating and non-eating events. Features were computed for each sensing measure to train a support vector machine model. This resulted in F1-scores of 0.82 for eating gestures, 0.94 for chewing food, and 0.58 for swallowing food.


Assuntos
Manipulação de Alimentos , Gestos , Humanos , Mastigação , Obesidade , Acelerometria
18.
Adv Mater ; 36(5): e2304604, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37656902

RESUMO

Self-powered skin optoelectronics fabricated on ultrathin polymer films is emerging as one of the most promising components for the next-generation Internet of Things (IoT) technology. However, a longstanding challenge is the device underperformance owing to the low process temperature of polymer substrates. In addition, broadband electroluminescence (EL) based on organic or polymer semiconductors inevitably suffers from periodic spectral distortion due to Fabry-Pérot (FP) interference upon substrate bending, preventing advanced applications. Here, ultraflexible skin optoelectronics integrating high-performance solar cells and monochromatic light-emitting diodes using solution-processed perovskite semiconductors is presented. n-i-p perovskite solar cells and perovskite nanocrystal light-emitting diodes (PNC-LEDs), with power-conversion and current efficiencies of 18.2% and 15.2 cd A-1 , respectively, are demonstrated on ultrathin polymer substrates with high thermal stability, which is a record-high efficiency for ultraflexible perovskite solar cell. The narrowband EL with a full width at half-maximum of 23 nm successfully eliminates FP interference, yielding bending-insensitive spectra even under 50% of mechanical compression. Photo-plethysmography using the skin optoelectronic device demonstrates a signal selectivity of 98.2% at 87 bpm pulse. The results presented here pave the way to inexpensive and high-performance ultrathin optoelectronics for self-powered applications such as wearable displays and indoor IoT sensors.

19.
Respir Physiol Neurobiol ; 320: 104185, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37935342

RESUMO

Acute, intermittent hypoxia (AIH) induces ventilatory long-term facilitation (vLTF) in awake, freely behaving rats under poikilocapnic and isocapnic experimental conditions. Establishing pre-clinical methods for vLTF induction that more closely align with successful protocols in humans and anesthetized rats would minimize dissonance in experimental findings and improve translational aspects of vLTF. Here, we tested several levels of low-dose CO2 supplementation during and after AIH to determine 1) the lowest amount of inspired CO2 that would maintain isocapnia in rats during a vLTF protocol, and 2) the net impact of supplemental CO2 on vLTF expression. Rats received one of four levels of inspired CO2 (0%, 0.5%, 1% or 2%) administered during AIH and for the 60 min following AIH to quantify vLTF. Our findings indicated that 2% inspired CO2 was sufficient to maintain isocapnia across the AIH protocol and reveal significant vLTF. These findings provide evidence-based support for using 2% supplemental CO2 during and after AIH when assessing vLTF in rats.


Assuntos
Dióxido de Carbono , Hipóxia , Ratos , Animais , Humanos , Dióxido de Carbono/farmacologia , Vigília , Fatores de Tempo , Suplementos Nutricionais
20.
J Clin Monit Comput ; 38(1): 121-130, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37715858

RESUMO

The purpose of this study was to evaluate the feasibility and accuracy of remote Video Plethysmography (VPPG) for contactless measurements of blood pressure (BP) and heart rate (HR) in adult surgical patients in a hospital setting. An iPad Pro was used to record a 1.5-minute facial video of the participant's face and VPPG was used to extract vital signs measurements. A standard medical device (Welch Allyn) was used for comparison to measure BP and HR. Trial registration: NCT05165381. Two-hundred-sixteen participants consented and completed the contactless BP and HR monitoring (mean age 54.1 ± 16.8 years, 58% male). The consent rate was 75% and VPPG was 99% successful in capturing BP and HR. VPPG predicted SBP, DBP, and HR with a measurement bias ± SD, -8.18 ± 16.44 mmHg, - 6.65 ± 9.59 mmHg, 0.09 ± 6.47 beats/min respectively. Pearson's correlation for all measurements between VPPG and standard medical device was significant. Correlation for SBP was moderate (0.48), DBP was weak (0.29), and HR was strong (0.85). Most patients were satisfied with the non-contact technology with an average rating of 8.7/10 and would recommend it for clinical use. VPPG was highly accurate in measuring HR, and is currently not accurate in measuring BP in surgical patients. The VPPG BP algorithm showed limitations in capturing individual variations in blood pressure, highlighting the need for further improvements to render it clinically effective across all ranges. Contactless vital signs monitoring was well-received and earned a high satisfaction score.


Assuntos
Assistência Perioperatória , Pletismografia , Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Pressão Sanguínea/fisiologia , Frequência Cardíaca
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...